Main menu:
RESEARCH
Metodi di Laboratorio messi a punto dal gruppo del Prof. Bellavite
Laboratory methods set-up by the Bellavite's group
Produzione di Acqua ossigenata con il metodo dell'acido omovanilico
Hydrogen peroxide production using the homovanillic acid technology
- Rossi, F., Bellavite, P., Dobrina, A., Dri, P. and Zabucchi, G. (1980) Oxidative metabolism of mononuclear phagocytes. In: Mononuclear Phagocytes: Functional Aspects (R. Van Furth ed.). Part II. Martinus Nijhoff Publ., The Hague, pp. 1187-1218.
Misura simultanea del superossido e della capacità opsonizzante del plasma (brevettato)
A clinical test for the evaluation of phagocyte function and serum opsonic activity (patented)
- Bellavite, P., Dri, P., Della Bianca, V. and Serra, M.C. (1983) The measurement of superoxide anion productionby granulocytes in whole blood. A clinical test for the evaluation of phagocyte function and serum opsonic activity. Eur. J. Clin. Invest. 13: 363-368.
Produzione del superossido con tecnologia dei biosensori
Superoxide production using biosensors electrochemistry
- McNeil, C.J., Smith, K.A., Bellavite, P. and Bannister, J.V. (1989) Application of the electrochemistry of cytochrome c to the measurement of superoxide radical production. Free Rad. Res. Commun. (Free Rad. Res). 7: 89-96.
Misura simultanea del superossido e della adesione dei leucociti in micropiastre di coltura
Simultaneous assay for oxidative metabolism and adhesion of human neutrophils in microplates
- Bellavite, P., Chirumbolo, S., Mansoldo, C., Gandini, G. and Dri, P. (1992) Simultaneous assay for oxidative metabolism and adhesion of human neutrophils. Evidence for correlations and dissociations of the two responses. J. Leukocyte Biol. 51: 329-335.
MIsura automatica dei cambimenti di forma dei neutrofili mediante analyzer
Automatic measurement of neutrophil shape changes by analyzer
- Lippi, U., Bellavite, P., Schinella, M. and Nicoli, M. (1992) Volume, conductivity and scatter changes of activated polymorphonuclear leukocytes: an estimation by coulter counter STKS analyzer. Int. J. Clin. Lab. Res. 21: 321-324.
Micrometodo per adesione piastrinica in micropiastre (brevettato)
Micromethod for platelet adhesion in colture plates (patented)
- Bellavite, P., Andrioli, G., Guzzo, P., Arigliano, P., Chirumbolo, S., Manzato, F. and Santonastaso, C. (1994) A colorimetric method for the measurement of platelet adhesion in microtiter plates. Anal. Biochem. 216: 444-450.
- Andrioli, G., Minuz, P., Solero, P., Pincelli, S., Ortolani, R., Lussignoli, S. and Bellavite, P. (2000) Defective platelet response to arachidonic acid and thromboxane A2 in subjects with PlA2 polymorphism of b3 subunit (glycoprotein IIIa) Brit. J. of Haematol. 110: 911-918.
Misura del potere antiossidante del plasma umano in micropiastre
A microplate-based assay of the antioxidant power of human plasma
- Lussignoli, S., Fraccaroli, M., Andrioli, G., Brocco, G. and Bellavite, P. (1999) A microplate-based colorimetric assay of the total peroxyl-radical trapping capability of human plasma. Anal. Biochem. 10: 38-44.
Un nuovo metodo per la valutazione citofluormetrica della funzione dei leucociti basofili umani
A new method for cytofluorimetric evaluation of human basophil leukocyte funtion
- Chirumbolo S., Vella A., Ortolani R., De Gironcoli M., Solero P., Tridente G., Bellavite P. (2008) Differential response of human basophil activation markers: a multi-parameter flow cytometry approach. Clinical and Molecular Allergy 2008, 16: 12
Un metodo multiparametrico per la tipizzazione leucocitaria
A multiparameter method for leukocyte immunotyping
- Ortolani R, Bellavite P, Chirumbolo S, Tridente G, Vella A (2009) Un metodo comparativo e integrato per lo studio dei sistemi complessi. In: Geni e comportamenti, scienza e arte della vita (F. Bottaccioli ed.). Red Edizioni, MIlano, pp. 147-154.
- Ortolani R, Bellavite P, Paiola F, Martini M, Marchesini M, Veneri D, Franchini M, Chirumbolo S, Tridente G, Vella A (2010) A comparative method for processing immunological parameters: developing an "Immunogram". Blood Transfus. 8: 118-125
Misura delle correnti elettrodermiche sui punti di agopuntura
Electrodermal measurement of acupuncture points
- Pontarollo F, Rapacioli G., Bellavite P. (2010) Increase of electrodermal activity of heart meridian during physical exercise: The significance of electrical values in acupuncture and diagnostic importance Complement. Ther. Clin. Pract. 16(3):149-53